operating,retention,degrees,through,rotatable,configurations

 


Head

Head
HM
Head only
HF
Head incl. fixed actuator

For gate switch and door lock configurations.

  • Rotatable through 360 degrees
  • Top and side entry
  • Operating force 5 to 10N
  • Retention force 1000N


TUV (EU+USA+Canada)

Images

Head
Head




Safety Data

Standards EN 60947-1:2007 (Low-voltage switchgear and control gear), EN60975-5-1:2004, EN62061:2005, EN/ISO13849-1:2008, EN50178:1997, EN60204-1:2006, EN50295:1999, GS-ET-19:04/2004
Certifications CE marked for all applicable directives
Category Cat. 4, PLe (EN/ISO 13849-1) and SIL3 (EN/IEC 62061)
Functional safety data* B10d 5.000.000
MTTfd High > 385 years (590 years)
CCF  
DC High 99% (with correct monitoring of both channels and including the opposite-mode monitoring switch)
PFHd [1/h] 5,90E-10

* eGard modules need to be constructed as a complete assembly to reach stated values

Downloads and drawings (Login required)

Datasheet HM, HF
Installation manual
 
2D drawing HM
2D drawing HF
3D model HM
3D model HF

Login

 
  Not a registered visitor? Click here.
Personal information


« Back