circuits,positive,contacts,operates,mechanical,removal,actuator,operation

 


Safety Switch

Safety Switch
SS

Can be driven by either the operation of the head module (removal of actuator) or a mechanical lock.

  • Operates on dual safety circuits
  • 2 force break positive make NC safety contacts (uses none of the I/O pins)


TUV (EU+USA+Canada)

I/O & Safety Circuits

Images

Safety Switch
Safety Switch




Safety Data

Standards EN 60947-1:2007 (Low-voltage switchgear and control gear), EN60975-5-1:2004, EN62061:2005, EN/ISO13849-1:2008, EN50178:1997, EN60204-1:2006, EN50295:1999, GS-ET-19:04/2004
Certifications CE marked for all applicable directives
Category Cat. 4, PLe (EN/ISO 13849-1) and SIL3 (EN/IEC 62061)
Functional safety data* B10d 5.000.000
MTTfd High > 385 years (590 years)
CCF  
DC High 99% (with correct monitoring of both channels and including the opposite-mode monitoring switch)
PFHd [1/h] 5,90E-10

* eGard modules need to be constructed as a complete assembly to reach stated values