fortress interlocks

 

Common assemblies


Login

 
  Not a registered visitor? Click here.
Personal information


 

HFSBSSBS

Safety gate switch with safety key module

HF      Head incl. fixed actuator
SB      Safety Key Module (with key)
SS      Safety Switch
BS      Safety Only Connector


This assembly can be used as a safety gate switch to monitor this status of the door. The safety key module additionally prevents accidental






Safety Data

Standards EN 60947-1:2007 (Low-voltage switchgear and control gear), EN60975-5-1:2004, EN62061:2005, EN/ISO13849-1:2008, EN50178:1997, EN60204-1:2006, EN50295:1999, GS-ET-19:04/2004
Certifications CE marked for all applicable directives
Category Cat. 4, PLe (EN/ISO 13849-1) and SIL3 (EN/IEC 62061)
Functional safety data* B10d 5.000.000
MTTfd High > 385 years (590 years)
CCF  
DC High 99% (with correct monitoring of both channels and including the opposite-mode monitoring switch)
PFHd [1/h] 5,90E-10

* eGard modules need to be constructed as a complete assembly to reach stated values

« Back