fortress interlocks

 

Common assemblies


Login

 
  Not a registered visitor? Click here.
Personal information


 

HCSUSBEUSSP3P6BC

HCSUSBEUSSP3P6BC
HCSUSBEUSSP3P6BC
+HCSUSBEUSSP3P6BC
Multiple Solenoid controlled Key release station with access request and reset function

HC    Cap
SN    Safety key adapter
SB    Safety key adapter
EU    Solenoid Controlled Lock
SS    Safety switch module
P3    Green illuminated pushbutton
P6    Blue illuminated pushbutton
BC    Control and safety connector (8 I/O)





Safety Data

Standards EN 60947-1:2007 (Low-voltage switchgear and control gear), EN60975-5-1:2004, EN62061:2005, EN/ISO13849-1:2008, EN50178:1997, EN60204-1:2006, EN50295:1999, GS-ET-19:04/2004
Certifications CE marked for all applicable directives
Category Cat. 4, PLe (EN/ISO 13849-1) and SIL3 (EN/IEC 62061)
Functional safety data* B10d 5.000.000
MTTfd High > 385 years (590 years)
CCF  
DC High 99% (with correct monitoring of both channels and including the opposite-mode monitoring switch)
PFHd [1/h] 5,90E-10

* eGard modules need to be constructed as a complete assembly to reach stated values