fortress interlocks

 

Common assemblies


Login

 
  Not a registered visitor? Click here.
Personal information


 

HFEUSSP3P6BA

HFEUSSP3P6BA
HFEUSSP3P6BA
+HFEUSSP3P6BA
Solenoid controlled safety gate switch with access request and reset function AS-i

HF    Actuator head
EU    Solenoid Controlled Lock
SS    Safety switch module
P3    Green illuminated pushbutton
P6    Blue illuminated pushbutton
BA    AS-i control and safety connector





Safety Data

Standards EN 60947-1:2007 (Low-voltage switchgear and control gear), EN60975-5-1:2004, EN62061:2005, EN/ISO13849-1:2008, EN50178:1997, EN60204-1:2006, EN50295:1999, GS-ET-19:04/2004
Certifications CE marked for all applicable directives
Category Cat. 4, PLe (EN/ISO 13849-1) and SIL3 (EN/IEC 62061)
Functional safety data* B10d 5.000.000
MTTfd High > 385 years (590 years)
CCF  
DC High 99% (with correct monitoring of both channels and including the opposite-mode monitoring switch)
PFHd [1/h] 5,90E-10

* eGard modules need to be constructed as a complete assembly to reach stated values

« Back