stainless,mastered,standard,fortress,characters,different,recorded,identify,engraving,database,maximum,reference,therefore,provided,engravings,required,engraved,continuous,supplied,operated,special,possible,besides,combinations,specific,provide,dustcover,combination,masterable,directions,insertion,allocated

 


Full Stainless Steel Masterable ML Lock with Stainless Steel Dustcover

Full Stainless Steel Masterable ML Lock with Stainless Steel Dustcover
MLSS

Fortress locks have over 200,000 different lock combinations. Besides the standard lock (CL) it is also possible to have a full stainless steel master series (MLSS) which can be operated by as special cut master key (MLK-SUGS) that fits any mastered lock in a specific mastered lock series. For each of use all Fortress locks provide key insertion in two directions.

The full stainless steel masterable ML lock (MLSS) is standard supplied with a stainless steel dustcover.

Each different key combination is allocated with an engraved code onto the lock and key, of up to maximum 30 characters (3 lines of 10 characters), this engraving code is used to identify locks and keys and is recorded in a database for continuous cross reference. Required engravings are therefore to be provided with each order.

Images

Full Stainless Steel Masterable ML Lock with Stainless Steel Dustcover




Safety Data

Standards 2006/95/EC (Low voltage directive), 2006/42/EC (The machinery directive), 2004/108/EC (The EMC Directive), EN60947-5-1:2004, EN61010-1:2001, EN1088:1996, EN12100-1:2003, EN12100-2:2003, EN13849-1: 2006, EN62061:2006, EN61000-6-2:2005, EN61000-6-3:2007
Certifications CE marked for all applicable directives
Category Cat. 4, PLe (EN/ISO 13849-1) and SIL3 (EN/IEC 62061)
Functional safety data* B10d 5.000.000
MTTfd High > 385 years (31250,0 years)
CCF 90%
DC High 99% (with correct monitoring of both channels and including the opposite-mode monitoring switch)
PFHd [1/h] 3,65E-09

* use the "Functional Safety Calculator" to calculate values with varying conditions
** amGard modules need to be constructed as a complete assembly to reach stated values

Downloads and drawings (Login required)

Datasheet MLIN, MLIS, MLSS
 
2D drawing MLSS
3D model MLSS

Login

 
  Not a registered visitor? Click here.
Personal information